SKU SMT6122 Category

SMT Superflex Cruz Nevo

SMT Supraflex Cruz - Next generation drug test for challenging veins

Supraflex Cruz represents the peak of drug exams (DES), combining extreme flexibility and uncompromising structural support. It is designed to proceed effortlessly with even the most challenging coronary anatomies, offering clinically proven safety and performance.

Why choose Supraflex Cruz?

  • Market leading navigability: The renewed, further improved thrust and stent flexibility make it exceptionally easy to export, even in very complicated and calcified veins.

  • Strong Z link structure: Unique Z design ensures excellent radial power (structural resistance) and optimal opening. This is a critical advantage, in particular: in bifurcation procedures (varicose veins) where precise placement is key.

  • Advanced three layer polymer: Stent coating is optimized in three steps:

    1. Protection: The first layer protects the medicine from damage during installation.

    2. Efficacy: The second layer releases 80% of the drug during the critical first month.

    3. Safety: The last polymer layer dissolves completely within three months, leaving only a clean, biocompatible surface.

  • Excellent overexpansion capability: The stent adapts widely to different vessel diameters, without compromising the integrity of the structure, which facilitates optimisation of the procedure.

  • Investigatively superior: Numerous clinical studies show that Supraflex Cruz is not only safe, but even better performance than many leading stents on the market.

SMT Superflex Cruz Nevo

SMT Supraflex Cruz - Next generation drug test for challenging veins

Supraflex Cruz represents the peak of drug exams (DES), combining extreme flexibility and uncompromising structural support. It is designed to proceed effortlessly with even the most challenging coronary anatomies, offering clinically proven safety and performance.

Why choose Supraflex Cruz?

  • Market leading navigability: The renewed, further improved thrust and stent flexibility make it exceptionally easy to export, even in very complicated and calcified veins.

  • Strong Z link structure: Unique Z design ensures excellent radial power (structural resistance) and optimal opening. This is a critical advantage, in particular: in bifurcation procedures (varicose veins) where precise placement is key.

  • Advanced three layer polymer: Stent coating is optimized in three steps:

    1. Protection: The first layer protects the medicine from damage during installation.

    2. Efficacy: The second layer releases 80% of the drug during the critical first month.

    3. Safety: The last polymer layer dissolves completely within three months, leaving only a clean, biocompatible surface.

  • Excellent overexpansion capability: The stent adapts widely to different vessel diameters, without compromising the integrity of the structure, which facilitates optimisation of the procedure.

  • Investigatively superior: Numerous clinical studies show that Supraflex Cruz is not only safe, but even better performance than many leading stents on the market.

Screenshot-2023-06-26-181638-e1687795352385
PFO Occlusive
vassular _ innovations _ 1 (1)
Septal Occluder
vassular _ innovations (1)
VSD Occlusive
vassular _ innovations _ 2 (1)
Duct Occlusive
Screenshot 2023-10-14 110256
Supraflex Cruz Nevo

SMT Superflex Cruz Nevo

Supraflex Cruz Nevo is a coronary artery test which has been shown to be safe in studies. Its structure is 60 µm in size. The dose of Sirolimus is three steps. In the first stage, which lasts during implantation, there is no medicine. The second floor is 80% of the drug, and it melts in one month. The rest of the medicine will be absorbed in three months. Nevo has continued to increase its local functionality. Nevo is easy to put in, even if the coronary artery structure is very challenging. Thanks to the Z link structure, bifurcations have good machinability and radialism is good. Talent Trial has shown that complications (e.g. instant restenosis) are very low and lower than those seen in the stent.
Screenshot 2023-10-14 110256
Screenshot 2023-10-14 121050

Talent Trial

Talent Trial showed that Supreme Cruz is a little better than the Xiensei stent. There is an even greater difference between three years of follow-up for Supraflex Cruz.

Supraflex Cruz Nevo

Nevo has improved the locality, although it has been good in the past. The profile of the tip and stent (when placed in place) is also low. The thrust has been increased. The Z link ensures good workability in bifurcations. Good overexpansion possibilities. Great healing profile.
Screenshot 2023-10-14 121238

Description

Technical information and availability:

  • Size: The largest range of markets - 88 different sizes ensures optimal fit for every anatomy.

  • Structure: Ultra thin stents (ostriches) improve endothelization.

  • Coating: Biodegradable polymer (Sirolimus medicine).


Accuracy and certainty for each intervention

Supraflex Cruz is a professional tool that removes obstacles to demanding measures. It allows you to rely on the progress of the stent and long-term clinical success.

[Download clinical trial summaries and technical brochure here (PDF)]


Ask for an offer or ask for more

Do you want to hear more about the clinical benefits of Supraflex Cruz or discuss the needs of your unit? Our experts are happy to help us find the best solutions.

[Ask for an offer or product presentation here]

Estimates

No product estimates yet.

Be the first to review "SMT Supraflex Cruz Nevo"

Your email address will not be published. Mandatory fields marked *

Design an optimal package for you - ask for an offer

Let's plan the perfect entity together. > If you need more, please submit an open invitation to tender. Our expert will help you put together a suitable equipment package for your work at the best price.

[👉 Send a call for tenders here]

Contact form (general)

You could also be interested in these

MAVIG RD614
Patient Thyroid Protection Thyroid and sternum are protected by first-class surgery, and...
ANDANZA Manometer S
The High-Pressure Device 40 atm - Accuracy and strength for high pressure expansion...
MAVIG WD300
Movable radiation protection wall A slightly curved lead acrylic shield does not distort the view and is...
SIS- MEDICAL NIC 1.1 Hydro
OPN NC 1.1 mm - The smallest market power pack for challenging CTO cases...
EnglishenEnglishEnglish